+8653181958192
service@makeronly.com

Verified Supplier | shandong hualing cable co.ltd
Products
  • Products
  • Factory
    Mobile
Cross-linked Polyethylene insulated Control Cable (GB/T9330.3)

Cross-linked Polyethylene insulated Control Cable (GB/T9330.3)

  • Min.Order Quantity: 1000
  • Supply Ability: 100000 per Month
  • Port: Qingdao,Tianjing,Shanghai
  • Payment Terms: T/T
Get Latest Price:
  • *Quantity: Meter
| Factory
Experience:1997-09-25
Buyer Protection

- Guaranteed Secure Payments on Every Order

- Refund if your item is not delivered or as described

- Buyer Protection after order confirmation

Latest Browsing
Product Details
  • Size:  600mm*600mm*600mm~~2000mm*2000mm*1300mm
  • Place of Origin:  Jinan,Shandong,China
  • Brand Name:  HL
  • Model Number:  KYJV,KYJVP,KYJVP2,KYJVP3,KYJV22,KYJVP2-22,KYJV32,KYJY,KYJYP,KYJYP2,KYJYP3,KYJY23,KYJYP2-23,KYJY33
  • Weight: 2300.000 kg

Cross-linked Polyethylene insulated Control Cable (GB/T9330.3)


Applications:

The product is applicable to wiring of electrical instrument in power distribution units with rated AC voltage of 450/750V and below.

Operation Characteristics:

1.The allowable long-term operation temperature for cable conductor is 90, and the cable laying temperature shall not be below 0.

2.The allowable maximum teperature of cable conductor in case of short circuit(with maximum duration no more than 5s) is 250

3.Allowable bend radius

Cable with armor or copper shielding structure shall not be less than 12 times external diameter of cable;

Flexible cable with braideded shielding or without shielding shall not be less than 6 times external diameter of cable.

Model and Name of Product

Model

Name

KYJV

Cross-linked Polyethylene insulated,PVC sheath, Control Cable

KYJVP

Cross-linked Polyethylene insulated,PVC sheath,Braid shield Control Cable

KYJVP2

Cross-linked Polyethylene insulated,PVC sheath,Copper strip wrapped shield Control Cable

KYJVP3

Cross-linked Polyethylene insulated,PVC sheath,Al cladding strip shield Control Cable

KYJV22

Cross-linked Polyethylene insulated,PVC sheath,Steel strip armored Control Cable

KYJVP2-22

Cross-linked Polyethylene insulated,PVC sheath,Copper strip shield,Steel strip armored Control Cable

KYJV32

Cross-linked Polyethylene insulated,PVC sheath,Steel wire armored  Control Cable

KYJY

Cross-linked Polyethylene insulated,polyolefine sheath, Control Cable

KYJYP

Cross-linked Polyethylene insulated,polyolefine sheath,Braid shield Control Cable

KYJYP2

Cross-linked Polyethylene insulated,polyolefine sheath,Copper strip wrapped shield Control Cable

KYJYP3

Cross-linked Polyethylene insulated,polyolefine sheath,Al cladding strip shield Control Cable

KYJY23

Cross-linked Polyethylene insulated,polyolefine sheath,Steel strip armored Control Cable

KYJYP2-23

Cross-linked Polyethylene insulated,polyolefine sheath,Copper strip shieldSteel strip armored Control Cable

KYJY33

Cross-linked Polyethylene insulated,polyolefine sheath,Steel wire armored  Control Cable

Noteunlisted cable could be customized according to chapter 4 in GB/T 9330.1-2008

Specifications

Model

Rated VoltageV

Nominal Section of Conductor (mm2

0.5

0.75

1.0

1.5

2.5

4

6

10

Number of Cores

KYJVKYJVP

KYJYKYJYP

450/750

/

261

214

210

KYJVP2KYJVP3

KYJYP2KYJYP3

/

461

414

410

KYJV22KYJY23

/

761

461

414

410

KYJVP2-22KYJYP2-23

/

761

461

414

410

KYJV32KYJY33

/

1961

761

414

410

Note1recommend numbers of cores are2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52 and 61 cores.

Number of Cores

Nominal Section of Wire(mm2

Insulation Thickness (mm)

KYJV

KYJVP

Sheath Thickness

(mm)

External Diameter of Cable

(mm)

Sheath Thickness

(mm)

External Diameter of Cable

(mm)

2

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.2

1.2

1.2

1.5

1.5

1.5

8.1

8.5

9.0

10.4

11.5

12.6

1.2

1.2

1.5

1.5

1.5

1.5

9.6

9.9

10.5

11.9

13.1

15.4

3

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.2

1.2

1.5

1.5

1.5

1.5

8.9

9.5

10.3

12.0

13.2

14.1

1.5

1.5

1.5

1.5

1.5

1.7

11.3

11.9

12.4

13.6

15.3

16.2

4

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

1.5

9.8

10.6

11.3

12.5

13.7

15.2

1.5

1.5

1.5

1.5

1.5

2.0

12.2

13.8

14.5

15.7

16.9

19.4

5

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

1.5

10.3

11.4

12.2

13.5

14.9

16.5

1.5

1.5

1.5

1.5

1.5

2.0

13.4

14.6

15.4

16.7

19.1

20.9

6

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

1.5

10.9

12.2

13.1

14.6

16.1

17.9

1.5

1.5

1.5

1.5

2.0

2.0

14.1

15.4

16.3

17.8

20.5

22.3

7

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

1.5

11.4

12.2

13.1

14.6

16.1

17.9

1.5

1.5

1.5

1.5

2.0

2.0

14.3

15.4

16.3

17.8

20.5

22.3

8

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

2.0

12.1

13.5

14.5

16.2

17.9

21.0

1.5

1.5

1.5

1.5

2.0

2.0

15.6

16.7

17.7

20.6

22.3

25.4

10

0.75

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

2.0

2.0

13.8

15.0

16.2

19.2

21.2

23.6

1.5

2.0

2.0

2.0

2.0

2.0

18.1

19.2

20.4

22.6

24.6

28.0

12

0.75

1

1.5

2.5

4

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

2.0

2.0

14.7

15.4

16.7

19.8

21.9

2.0

2.0

2.0

2.0

2.0

18.4

19.6

20.9

23.2

25.3

14

0.75

1

1.5

2.5

4

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

2.0

2.0

15.4

16.1

17.5

20.7

22.9

2.0

2.0

2.0

2.0

2.0

18.9

20.3

21.7

24.1

26.3

16

0.75

1

1.5

2.5

0.7

0.7

0.7

0.7

1.5

1.5

2.0

2.0

16.2

17.0

19.4

21.7

2.0

2.0

2.0

2.0

19.8

21.2

22.6

25.1

19

0.75

1

1.5

2.5

0.7

0.7

0.7

0.7

1.5

1.5

2.0

2.0

15.7

17 8

20.3

22.8

2.0

2.0

2.0

2.0

20.4

22.0

23.5

26.2

24

0.75

1

1.5

2.5

0.7

0.7

0.7

0.7

1.5

1.5

2.0

2.0

19.9

21.6

23.4

264

2.0

2.0

2.0

2.0

22.9

24.8

26.6

298

27

0.75

1

1.5

2.5

0.7

0.7

0.7

0.7

1.5

1.5

2.0

2.0

21.2

22.0

23.9

26.9

2.0

2.0

2.0

2.0

24.1

25.3

27.1

30.3

l Cross-linked Polyethylene insulated,,PVC sheath, Control Cable(solid conductor)

Number of Cores

Nominal Section of Wire(mm2

Insulation Thickness

KYJV

KYJVP

KYJV22

Sheath Thickness

External Diameter of Cable

Sheath Thickness

External Diameter of Cable

Sheath Thickness

External Diameter of Cable

4

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

10.1

10.8

11.8

13.0

14.2

1.5

1.5

1.5

1.5

1.5

13.3

14.0

15.0

16.2

17.4

1.5

1.5

1.5

1.5

1.5

14.0

14.5

16.0

17.0

18.5

5

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

10.8

11.6

12.7

14.1

15.4

1.5

1.5

1.5

1.5

2.0

14.0

14.8

15.9

17.3

19.9

1.5

1.5

1.5

1.5

1.5

15.0

16.0

17.9

18.5

20.0

6

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

11.6

12.5

13.7

15.2

16.7

1.5

1.5

1.5

1.5

2.0

14.8

15.7

16.9

19.4

21.3

1.5

1.5

1.5

1.5

1.5

15.9

17.0

17.8

20.1

21.0

7

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

1.5

11.6

12.5

13.7

15.2

16.7

1.5

1.5

1.5

2.0

2.0

14.8

15.7

16.9

19.4

21.1

1.5

1.5

1.5

1.5

1.5

16.0

17.3

18.2

20.0

22.0

8

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

1.5

2.0

12.8

13.8

15.2

16.9

19.6

1.5

1.5

1.5

2.0

2.0

16.0

17.0

19.4

21.3

24.0

1.5

1.5

1.5

1.5

1.5

17.2

18.0

20.6

21.3

24.0

10

1

1.5

2.5

4

6

0.7

0.7

0.7

0.7

0.7

1.5

1.5

1.5

2.0

2.0

14.2

15.4

17.0

20.0

22.1

1.5

1.5

1.5

2.0

2.0

17.4

19.4

21.6

23.6

25.4

1.5

1.5

1.5

1.5

1.5

18.5

20.0

21.6

24.6

26.5

12

1

1.5

2.5

4

0.7

0.7

0.7

0.7

1.5

1.5

1.5

2.0

14.6

15.9

17.5

20.6

1.5

2.0

2.0

2.0

17.8

20.1

21.9

24.0

1.5

1.5

1.5

1.5

17.2

20.4

22.2

25.0

14

1

1.5

2.5

0.7

0.7

0.7

1.5

1.5

2.0

15.3

16.6

19.4

2.0

2.0

2.0

19.5

20.7

22.8

1.5

1.5

1.5

19.7

20.8

23.5

16

1

1.5

2.5

0.7

0.7

0.7

1.5

1.5

2.0

16.0

17.4

20.3

2.0

2.0

2.0

20.2

21.6

23.7

1.5

1.5

1.5

20.4

21.8

24.5

19

1

1.5

2.5

0.7

0.7

0.7

1.5

2.0

2.0

16.8

19.3

21.3

2.0

2.0

2.0

21.0

22.5

24.7

1.5

1.5

1.5

21.0

23.5

25.5

24

1

1.5

2.5

0.7

0.7

0.7

2.0

2.0

2.0

20.4

22.0

24.5

2.0

2.0

2.0

23.8

25.6

28.0

1.5

1.5

1.5

24.5

26.6

29.0

27

1

1.5

2.5

0.7

0.7

0.7

2.0

2.0

2.0

20.8

22.6

25.1

2.0

2.0

2.0

24.0

25.8

28.5

1.5

1.5

1.5

25.0

27.1

29.5

30

1

1.5

2.5

0.7

0.7

0.7

2.0

2.0

2.0

21.5

23.5

25.0

2.0

2.0

2.0

24.9

26.6

29.4

1.5

1.5

1.5

25.9

27.9

32.3

33

1

1.5

2.5

0.7

0.7

0.7

2.0

2.0

2.0

22.2

24.2

25.9

2.0

2.0

2.0

25.8

27.6

30.3

1.5

1.5

1.5

26.5

29.5

32.0

37

1

1.5

2.5

0.7

0.7

0.7

2.0

2.0

2.0

23.0

25.1

27.9

2.0

2.0

2.0

26.2

28.3

31.4

1.5

1.5

1.5

27.1

30.3

33.1

Note: Weight of different models is different,more details are available on catalogue.

  • Size:  600mm*600mm*600mm~~2000mm*2000mm*1300mm
  • Place of Origin:  Jinan,Shandong,China
  • Brand Name:  HL
  • Model Number:  KYJV,KYJVP,KYJVP2,KYJVP3,KYJV22,KYJVP2-22,KYJV32,KYJY,KYJYP,KYJYP2,KYJYP3,KYJY23,KYJYP2-23,KYJY33
  • Weight: 2300.000 kg
Send your message to this factory
   
To: shandong hualing cable co.ltd
*Message:
Your message must be between 4-5000 characters
*Quantity: Meter
 
 
Auto Transportation,Trailers
Agriculture Food,Fertilizer,Nitrogen Fertilizer
Auto Transportation,Automobiles
Photo copy paper
Auto Transportation,Trailers